Author Affiliation: Dr Wilson is an independent working researcher working out of Brentwood, Tennessee.
New cardiac procedures are often used excessively, suggesting that physicians tend to overestimate the benefits of new procedures.1- 2 Randomized trial reports may contribute to this problem by exaggerating procedural benefits. I have previously noted that a variety of rhetorical strategies that emphasize device benefits were used in reporting implantable cardioverter defibrillator (ICD) primary prevention trials, including message framing, underreporting of complications, and interpretation bias.3 Other investigators have also noted widespread use of such techniques in randomized trial reports.4- 7 The purpose of this report was to determine the extent to which rhetorical strategies were used to emphasize device benefits in cardiac resynchronization therapy (CRT) trial reports.
The methods used in this study have been described in detail previously.3 In brief, MEDLINE, the Cochrane Trial Register and Library, and CRT reviews were searched for all randomized trials in which CRT was compared with no pacing; enrollment was more than 100 patients; and the primary outcome was survival, functional capacity, and/or hospitalization.
Publications were analyzed for the presence of 4 rhetorical strategies that can be used to emphasize treatment efficacy: message framing, use of ratios rather than absolute values to report results, underreporting of harms, and interpretation bias. Message framing was considered present when the trial objective, stated in the abstract or introduction, failed to include the evaluation of CRT harms and/or the introduction only included background information supporting CRT efficacy.
The exclusive use of ratios to present primary outcome results was considered evidence that ratios were used to emphasize CRT benefits. Complication data were considered to be underreported when the abstract did not include information about CRT complications and/or the results section did not contain complete information about the rates of unsuccessful device implantation, procedural complications, and/or postimplant complications. Interpretative bias was considered present when (1) important trial limitations were not mentioned and discussed; (2) CRT complications were not discussed despite the presence of significant device complications in the study population; (3) the risks vs benefits of CRT therapy were not compared, including how the frequency of risks should alter use of CRTs; (4) there was no mention that CRT benefits are likely to be less in clinical practice than in a clinical trial; and/or (5) trial conclusions indicated that CRT therapy is unequivocally beneficial despite failure of the trial to demonstrate a significant effect on the primary efficacy end point.
The search criteria identified 10 trial publications (Figure).8- 17 Evidence of message framing was noted in both abstracts and introductory sections. In 8 abstracts and 9 introductory sections, the stated objective of the trial was to evaluate CRT benefits with no mention of evaluating CRT harms. In 7 introductory sections, only background information that supported CRT efficacy is noted, with no mention of negative CRT study findings or reports of high CRT complication rates. Primary end point data were reported using absolute values in the results section of 9 publications.
Figure. Results of Publication Analysis. CARE-HF indicates Cardiac Resynchronization in Heart Failure Study; COMPANION, Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure; CRT, cardiac resynchronization therapy; ICD, implantable cardioverter/defibrillator; MADIT-CRT, Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy; MIRACLE, Multicenter InSync Randomized Clinical Evaluation; MIRACLE ICD, Multicenter InSync ICD Randomized Clinical Evaluation; RAFT, Resynchronization-Defibrillation for Ambulatory Heart Failure Trial; RethinQ, Cardiac Resynchronization Therapy in Patients with Heart Failure and Narrow QRS; and REVERSE, Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction.
Device-related adverse events were underreported. Adverse events from CRT are not mentioned in 8 of the publication abstracts. Unsuccessful initial CRT implant rates are described in all publications, with a mean 8% of patients having an unsuccessful implant (range, 1%-14%). Procedural complication rates and a description of the complications are provided in only 6 publications, with a mean 15.7% of patients experiencing complications (range, 4%-28%). Three additional publications provide partial descriptions of procedural complications. Postimplant complication data are clearly reported in only 4 publications, with a mean 26.1% of patients experiencing complications (range, 7%-46%). In 1 publication, annualized complication event rates are noted but without describing specific complications. In 1 publication, composite procedural and postprocedural complications rates are reported. In all 10 publications, only 1 table of a total 51 tables and figures is used to describe adverse events.
Trial interpretation in all publications appeared to be biased in favor of CRT efficacy. Six of the publications contain no mention of device adverse effects in the discussion section. The other 4 publications mention CRT adverse effects but do not include any further commentary such as a comparison of the percentage of patients who improved with CRT therapy vs the percentage who experienced device adverse effects, any discussion of how the presence of adverse effects should influence device use, or any comment that CRT benefits are likely to be less in clinical practice than in a randomized trial.
In the MIRACLE (Multicenter InSync Randomized Clinical Evaluation),8 MIRACLE ICD (Multicenter InSync ICD Randomized Clinical Evaluation),9 MIRACLE ICD II,11 and REVERSE (Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction)15 trials, patients were randomized only after successful device implantation with no discussion of how such a design reduces the ability to generalize results. The CONTAK CD10 study was changed from a crossover to a parallel design, and the primary end point altered with no discussion of the impact on trial analysis.
Cardiac resynchronization therapy is a relatively new treatment for heart failure that was first approved by the US Food and Drug Administration in 2001. This approval is based on the pivotal clinical trials that discuss risks and benefits of CRT.
My analysis of these trials and publications suggests that rhetorical techniques were used to emphasize the benefits and minimize the harms of CRT. My recent analysis of implantable defibrillator primary prevention trial reports led to similar conclusions.3 In fact, the use of specific rhetorical strategies was strikingly similar in the CRT and ICD reports, particularly the tendency to underreport complications and to ignore device complications in discussion sections.
This use of rhetoric has likely contributed to an overly optimistic view of CRT and ICD benefits and may help to explain why cardiac devices are frequently implanted in patient groups that were excluded from device trials, such as patients older than 80 years, and why device implant complication rates in the Medicare population are higher than expected.1- 2
Correspondence: Dr Wilson, 503 Dekemont Ln, Brentwood, TN 37027 (jwilson870@hotmail.com).
Published Online: June 13, 2011. doi:10.1001/archinternmed.2011.248
Financial Disclosure: None reported.
Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature
Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal
Instructions
Thank you for submitting a comment on this article. It will be reviewed by JAMA Internal Medicine editors. You will be notified when your comment has been published. Comments should not exceed 500 words of text and 10 references.
Do not submit personal medical questions or information that could identify a specific patient, questions about a particular case, or general inquiries to an author. Only content that has not been published, posted, or submitted elsewhere should be submitted. By submitting this Comment, you and any coauthors transfer copyright to the journal if your Comment is posted.
* = Required Field
Disclosure of Any Conflicts of Interest* Indicate all relevant conflicts of interest of each author below, including all relevant financial interests, activities, and relationships within the past 3 years including, but not limited to, employment, affiliation, grants or funding, consultancies, honoraria or payment, speakers’ bureaus, stock ownership or options, expert testimony, royalties, donation of medical equipment, or patents planned, pending, or issued. If all authors have none, check "No potential conflicts or relevant financial interests" in the box below. Please also indicate any funding received in support of this work. The information will be posted with your response.
Register and get free email Table of Contents alerts, saved searches, PowerPoint downloads, CME quizzes, and more
Subscribe for full-text access to content from 1998 forward and a host of useful features
Activate your current subscription (AMA members and current subscribers)
Purchase Online Access to this article for 24 hours
Some tools below are only available to our subscribers or users with an online account.
Download citation file:
Web of Science® Times Cited: 3
Customize your page view by dragging & repositioning the boxes below.
Care at the Close of Life EDUCATION GUIDESPalliative Care for Patients with Heart Failure
All results at JAMAevidence.com >
and access these and other features:
Register Now
Enter your username and email address. We'll send you a link to reset your password.
Enter your username and email address. We'll send instructions on how to reset your password to the email address we have on record.
Need assistance?
Athens and Shibboleth are access management services that provide single sign-on to protected resources. They replace the multiple user names and passwords necessary to access subscription-based content with a single user name and password that can be entered once per session. It operates independently of a user's location or IP address. If your institution uses Athens or Shibboleth authentication, please contact your site administrator to receive your user name and password.